Tensile test according to DIN EN ISO 527-2. Young’s modulus, tensile strength, and maximum elongation were determined. The tests were performed on a UPM 1446 testing machine from Zwick Roell (Ulm, Germany) with 5 specimens of each batch at a test speed of 5 mm/min. 